Recessed lights turning off by themselvesMadrid, Madrid

Recessed (can) lights that turn off by themselves and come back on after a few minutes are almost always activating their built-in thermal protection cutoff. Every recessed housing has a thermal switch that kills power when the fixture overheats, preventing a fire in the ceiling cavity. Once it cools, the light comes back on — and the cycle repeats. The most common cause is using a bulb with higher wattage than the fixture is rated for: a 75W or 100W incandescent in a can rated for 60W generates far too much heat. The second cause is insulation contact. Non-IC-rated (insulation contact) housings require a minimum 3-inch clearance from insulation. If blown-in or batt insulation has been piled against or over a non-IC can, heat cannot dissipate and the thermal switch trips. Older non-IC cans installed in the 1980s and 1990s are especially prone to this after attic insulation upgrades. The easiest and safest fix is retrofitting with LED modules or LED bulbs, which produce a fraction of the heat — a 10W LED replaces a 65W incandescent flood. LED retrofit kits that snap into the existing housing cost $15–$40 per light and can be self-installed. If the housing itself is damaged, corroded, or non-IC-rated in an insulated ceiling, an electrician can replace it with a modern IC-rated, airtight housing ($100–$250 per fixture installed). A licensed electrician should also inspect the wiring connections inside the junction box — loose wire nuts or backstabbed connections in the fixture's J-box can arc and cause intermittent shutoffs ($75–$150 per service call). If multiple recessed lights on the same circuit are cycling off, the circuit itself may be overloaded.

Waarom dit veel voorkomt in Madrid

Many pre-1990 Madrid buildings carry undersized wiring that cannot support modern dual heating-and-cooling loads, and panels frequently lack the residual-current devices required since 2002. The combination of winter electric heating and summer AC pushes circuits hard, and any installation work requires a completion certificate filed with the Comunidad de Madrid industry directorate.

Who to call

For this problem in Madrid, call a: Elektricien

Vind een Elektricien in Madrid

Symptoms to look for

  • Recessed light turns off after being on for a while, then turns back on after cooling
  • Bulb feels extremely hot to the touch when the light shuts off
  • Burning or hot plastic smell near the ceiling around the light
  • Light flickers or dims before shutting off completely
  • Multiple recessed lights on the same circuit cycling off together

Spoeddienst in Madrid

Emergency services in Madrid respond within 30–75 minutes in the central districts. Callout rates run €55–€140 plus €45–€75/hour including IVA — among Spain's highest after Barcelona. Winter cold snaps drive burst-pipe and heating-failure surges that can stretch waits; verify the contractor is a registered instalador autorizado with the Comunidad de Madrid before granting entry.